Fixed LWIR Lens 4mm f/1.2丨mini lens

Fixed LWIR Lens 4mm f/1.2丨mini lens
group name
Fixed Athermalized LWIR Lens (1-FOV)
Min Order
1 piece
brand name
Quanhom Optronics
model
GLA0412ZSD
Nearest port for product export
Shanghai, Ningbo, Tianjin, Khorgos
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, CIP, FCA, CPT, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, D/P D/A, PayPal, Westem Union
update time
Thu, 21 Nov 2024 15:31:01 GMT

Paramtents

  • LWIR Lens 4mm f/1.2

  • Applications Security and Surveillance

  • Mechanical Interface Thread

Packging & Delivery

  • Min Order1 piece

Briefing

Fixed LWIR Lens 4mm f/1.2 ,can be applied to Enhanced Vision.

Detailed

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
20μm
43.6°
77.3°
80.1°
87.7°
/
/
/
/
17μm
37.6°
68.4°
71.1°
78.4°
/
/
/
/
12μm
27.0°
51.3°
53.5°
59.9°
/
/
/
/

Optical

Focal Length[mm]
4
F/#
1.2
Wave Length
8-14μm
Focus Range
1m-Infinity

Mechanical

Interface
Thread
Focus Mechanism
Fixed Athermalized
Dimensions [mm]
Φ32x30.73
Weight
52g

Environmental

Operating Temperature
-40℃ to +80
External Coating
DLC
Sealing
IP67
Download document
file name
type
download
PDF
FAQ
- Why the lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), which can be refocused;

2. If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

3. Hardware problems, such as the potentiometer does not work, replace the hardware that does not work.

- Why cannot the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;

3. Confirm the wiring of the module or the control board, maybe the wiring is loose;

4. Module or control board hardware problem, replace the hardware.