Follow us :

Fixed Athermalized LWIR Lens 60mm f/1.0

Fixed Athermalized LWIR Lens 60mm f/1.0
group name
Fixed Athermalized LWIR Lens (1-FOV)
Min Order
1 piece
brand name
Quanhom Optronics
model
GLA6010D
Nearest port for product export
Shanghai, Ningbo, Tianjin, Khorgos
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, CIP, FCA, CPT, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, D/P D/A, PayPal, Westem Union
update time
Sat, 23 Nov 2024 16:23:43 GMT

Paramtents

  • LWIR Lens 60mm f/1.0

  • Applications Security and Surveillance

  • Mechanical Interface Thread

Packging & Delivery

  • Min Order1 piece

Briefing

Fixed LWIR Lens 60mm f/1.0,can be applied to Security & Surveillance.

Detailed

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
25μm
3.8°
3.7°
8.0°
9.1°
/
/
/
/
17μm
2.6°
5.2°
5.5°
6.2°
10.4°
10.4°
/
/
12μm
1.8°
3.7°
3.8°
4.4°
7.3°
7.3°
/
/

Optical

Focal Length[mm]
60
F/#
1.0
Detector
640x512, 17μm
Wavelength
8-14μm
Format
Φ14

Mechanical

Interface
Thread M34x0.75
Focus Mechanism
Fixed Athermalized
Dimensions [mm]
Φ71.5x74.67
Weight
<240g

Environmental

Operating Temperature
-40℃ to +80
External Coating
DLC
Sealing
IP67
Download document
file name
type
download
PDF
FAQ
- Why the lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), can be refocused;

2.If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

3. Hardware problems, such as potentiometer does not work, replace the hardware that does not work.

- Why can not the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2.Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;

3. Confirm the wiring of the module or the control board, maybe the wiring is loose;

4.Module or control board hardware problem, replace the hardware.

APPLICATIONS
Airborne
Enhanced Vision
Hand-held Thermal Imaging Devices
Homeland Security
Maritime & Naval
Security & Surveillance