Follow us :

Motorized Continuous Zoom IR Lens 25mm-225mm f/0.85-1.3 F1.3 LWIR

Motorized Continuous Zoom IR Lens 25mm-225mm f/0.85-1.3 F1.3 LWIR
group name
HD Lenses
Min Order
1 piece
brand name
Quanhom Optronics
model
GCZ92513KD
Nearest port for product export
Shanghai, Ningbo, Tianjin, Khorgos
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, CIP, FCA, CPT, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, D/P D/A, PayPal, Westem Union
update time
Thu, 21 Nov 2024 17:55:48 GMT

Paramtents

  • LWIR Lens 25-225mm f/0.85-1.3

  • Applications Security and Surveillance

  • Focus Mechanism Motorized

Packging & Delivery

  • Min Order1 piece

Briefing

IR lens, LWIR Lens. Stable operation, optional encoder motor.

Detailed

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
25μm
/
/
/
2.4°-21.7°
/
/
6.5°-54.2°
/
17μm
/
/
1.5°-13°
1.7°-14.9°
2.8°-24.6°
2.8°-24.6°
4.4°-38.4°
/
12μm
/
/
1°-9.2°
1.2°-10.5°
2°-17.5°
2°-17.5°
3.1°-24.7°
3.9°-34.2°

Optical

Focal Length[mm]
25-225mm 9X Continuous Zoom
F/#
0.85-1.3
Wavelength
8-12µm

Focus Range

15m-Infinity

Mechanical

Interface
Flange
Focus Mechanism
Motorized
Dimensions [mm]
Ø206x 307.4(Front flange Φ235)
Weight
<6100g

Electrical & Communications

Power Input
DC 12V 
Communications
Optional

Environmental

Operating Temperature
-40℃ to +60
Storage Temperature
-40℃ to +80
External Coating
DLC
Front Element Sealing
IP67
Download document
FAQ
- Why is the lens autofocus not clear?

There are many reasons why the lens autofocus is not clearl; the main reasons are as follows which can be checked one by one:

1. During the focusing process, if there is a large moving target in the lens screen (occupying more than 1/3 of the picture), just refocus;

2. If the lens is used for a long time, and the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, adjust the module or control board parameters to make the focus clear again;

3. For hardware problems such as the potentiometer not working, replace the hardware that does not work.

- Why can not the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected; the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, which may be incompatible with the computer or of the wrong type;

3. Check if the wiring of the module or the control board is loose;

4. For module or control board hardware problems, replace the hardware.