Follow us :

LWIR Continuous Zoom Lens 18-54mm f/0.9-1.2

LWIR Continuous Zoom Lens 18-54mm f/0.9-1.2
LWIR Continuous Zoom Lens 18-54mm f/0.9-1.2LWIR Continuous Zoom Lens 18-54mm f/0.9-1.2
group name
HD Lenses
Min Order
1 piece
brand name
Quanhom Optronics
model
GCZ31812KD
Nearest port for product export
Shanghai, Ningbo, Tianjin, Khorgos
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, CIP, FCA, CPT, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, D/P D/A, PayPal, Westem Union
update time
Thu, 21 Nov 2024 20:28:59 GMT

Paramtents

  • LWIR Lens 18-54mm f/0.9-1.2

  • Applications Security and Surveillance

  • Focus Mechanism Motorized

Packging & Delivery

  • Min Order1 piece

Briefing

LWIR Continuous Zoom Lens .can be applied to Thermal Imaging Body Temperature Screening.

Detailed

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160X120
320X240
336X266
384X288
640X480
640X512
1024X768
1280X1034
25μm
4.2°-12.7°
8.5°-25.1°
8.9°-26.3°
10.2°-29.9°
/
/
/
/
17μm
2.9°-8.6°
5.8°-17.2°
6.1°-1.8°
6.9°-20.6°
11.5°-33.6°
11.5°-33.6°
/
/
12μm
2°-6.1°
4.1°-12.2°
4.3°-12.8°
4.9°-14.6°
8.1°-24.1°
8.1°-24.1°
13°-37.7°
16.2°-46.2°

Optical

Focal Length[mm]
18-54
F/#
0.9-1.2
Wavelength
8-12μm
Focus Range
2m-Infinity / 5m-Infinity

Mechanical

Interface
Flange
Focus Mechanism
Motorized
Dimensions [mm]
Ø108 x 151.8
Weight
1.3kg

Electrical & Communications

Power Input
DC 12V Average

Environmental

Operating Temperature
-40℃ to +70
Storage Temperature
-50℃ to +80
Front Element Sealing
IP68
External Coating
DLC
Download document
FAQ
- Why the lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), can be refocused;

2.If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

3. Hardware problems, such as potentiometer does not work, replace the hardware that does not work.

- Why can not the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2.Replace the data cable,maybe the data cable is not compatible with the computer or the cable data is wrongly selected;

3. Confirm the wiring of the module or the control board, maybe the wiring is loose;

4.Module or control board hardware problem, replace the hardware.

VIDEO
APPLICATIONS
Homeland Security
Maritime & Naval
Security & Surveillance