Follow us :

Fixed Athermalized LWIR Lens 5.8mm f/1.0

Fixed Athermalized LWIR Lens 5.8mm f/1.0
group name
Fixed Athermalized LWIR Lens (1-FOV)
Min Order
1 piece
brand name
Quanhom Optronics
model
GLA05810A
Nearest port for product export
Shanghai, Ningbo, Tianjin, Khorgos
Delivery clauses under the trade mode
FOB, CFR, CIF, EXW, CIP, FCA, CPT, DDP, DDU, Express Delivery, DAF, DES
Acceptable payment methods
T/T, D/P D/A, PayPal, Westem Union
update time
Fri, 22 Nov 2024 08:54:10 GMT

Paramtents

  • LWIR Lens 5.8mm f/1.0

  • Applications Security and Surveillance

  • Mechanical Interface Thread

Packging & Delivery

  • Min Order1 piece

Briefing

Fixed Athermalized LWIR Lens 5.8mm f/1.0,can be applied to Security & Surveillance.

Detailed

  • Specifications
  • Download file
  • FAQ
  • Video
  • Applications
Specifications
HFOV
160x120
320x240
336x256
384x288
640x480
640x512
1024x768
1280x1024
17μm
26.4°
50.2°
52.4°
58.7°
86.3°
86.3°
/
/
12μm
18.8°
36.6°
38.3°
43.3°
67.0°
67.0°
/
/

Optical

Focal Length[mm]
5.8
F/#
1.0
Wavelength
8-12μm
Format
Φ14

Mechanical

Interface
Thread
Focus Mechanism
Fixed Athermalized
Dimensions [mm]
Φ56x53.7
Weight
<113g

Environmental

Operating Temperature
-40℃ to +80
Storage Temperature
-45℃ to +85
External Coating
AR
Sealing
IP67
Download document
FAQ
- Why the lens autofocus is not clear?

There are many reasons why the lens autofocus is not clear, the main reasons are as follows which can be checked one by one:

1. During the focusing process, there is a large moving target in the lens screen (occupying more than 1/3 of the picture), which can be refocused;

2. If the lens is used for a long time, the gear, CAM and other transmission parts wear and tear, resulting in unclear focus, the module or control board parameters can be adjusted to make the focus clear again;

3. Hardware problems, such as the potentiometer does not work, replace the hardware that does not work.

- Why cannot the lens control board or module connect to the computer?

There are many reasons why the lens control board and the computer cannot be connected, the main reasons are as follows which can be checked one by one:

1. Replace the USB port, which may be incompatible with the data cable;

2. Replace the data cable, maybe the data cable is not compatible with the computer or the cable data is wrongly selected;

3. Confirm the wiring of the module or the control board, maybe the wiring is loose;

4. Module or control board hardware problem, replace the hardware.

VIDEO
APPLICATIONS
Airborne
Enhanced Vision
Hand-held Thermal Imaging Devices
Homeland Security
Maritime & Naval
Security & Surveillance